Single Gas Clip Infrared Gas Detector
SGC-C / SGC-H / SGC-O
Finally a reliable portable single gas detector that ensures constant protection against toxic gas in the harshest of working conditions.
- 2 year runtime – 2 year life!
- No charging ever! No calibration needed!
- Unmatched sensor reliability for H2S, CO or O2
- Adjustable alarm set points & real-time gas reading capability
- 0.1 ppm resolution for H2S sensor and display
- Two-way IR comms for event downloads, bump tests & updates
- Programmable individual detector identification
- Simple to use one button operation
- “Bump Check” confirmation/identification
- No hidden service charges or maintenance fees
- Lightweight & durable – clamps on tight with alligator clip
Description
Tough!
Whether it’s the hottest or the coldest environment, our Single Gas Clip is designed and tested to provide worker safety in the harshest working conditions.
Easy to own and operate.
At Gas Clip Technologies, we use the latest technology to enhance customer safety. We quality test 100% of our detectors, not just a random sample. That’s why we can offer a low cost of ownership. There are no hidden service charges, just reliable detectors that will help your facility workers and contractors do their jobs safely, productively and cost effectively.
Unmatched safety, reliability and productivity
For unmatched safety, reliability and productivity, choose the world’s most advanced single gas detector, the Single Gas Clip.
Be sure to compare these features to our Multi Gas Clip and Single Gas Clip Plus to find the right product for your current application.
Datasheet
SPECIFICATIONS
| Size | 85.5 x 48 x 29 mm / 3.4 H x 1.9 W x 1.1 D in. |
| Weight | 76g / 2.7 oz. |
| Temperature | H2S: -40°C to +50°C / -40°F to +122°F |
| CO: -40°C to +50°C / -40°F to +122°F | |
| O2: -35°C to +50°C / -31°F to +122°F | |
| Humidity | 5% to 95% RH (non-condensing) |
| Battery Life | Two Years |
| Alarms | Visual, vibrating & audible (minimum 95 dB) |
| Detector life countdown (EOL), Low, High & Over limit (OL) | |
| Display | High viewing angle Alphanumeric Liquid Crystal Display |
| Logs | 25 Events – newer events replace older events |
| Tests | Full function self-test upon activation and every 20 hours |
| Continuous automatic battery tests | |
| Ratings, Certifications and Approvals | EMC Directive 2004/108/EC IP 67 |
| UL-913 & CAN/CSA-C22.2 No. 157 | |
| Class I Divisions 1 & 2, Groups A, B, C and D | |
| Class I, Zone 0, AEx ia IIC T4 Ga | |
| UL 60079-0, UL 60079-11 | |
| ATEX: II 1 G T4 Ex ia IIC T4 | |
| IECEx: EX ia IIC T4 | |
| InMetro: IEx 15.0058 Ex ia IIC T4 Ga | |
| (-40˚C (H2S,CO) / -35˚C (O2) ≤ Ta ≤ +50˚C) | |
| Warranty | Full Two years |
| Gases | H2S Measuring range: 0-100 ppm |
| Low alarm limit: 10 ppm – High alarm limit: 15 ppm | |
| CO Measuring range: 0-300 ppm | |
| Low alarm limit: 35 ppm – High alarm limit: 200 ppm | |
| O2 Measuring range: 0-30% by vol. | |
| Low alarm limit: 19.5% – High alarm limit: 23.5% | |
| *Note: Alarm set points listed above are factory default. These set points can be changed using the GCT IR Link (sold separately). | |
| Sensor Type | H2S, CO & O2 – Plug-in electrochemical cell |