  • Vaisala BAROCAP®  sensor
  • Accurate measurement
  • Excellent long-term stability
  • Added reliability through redundancy
  • Graphical trend display with 1-year history data
  • Altitude corrected pressure (QFE, QNH)
  • For professional use in meteorology, aviation, laboratories, and demanding industrial applications

Vaisala

Category:

Description

Inputs and Outputs

  • Supply voltage   10 … 35 VDC
  • Supply voltage sensitivity    negligible
  • Typical power consumption at +20 °C (Uin 24 VDC, one pressure sensor)
  • RS-232 25 mA
  • RS-485 40 mA
  • Uout 25 mA
  • I out 40 mA
  • display and backlight +20 mA
  • Serial I/O RS232C, RS485/422
  • Pressure units hPa, mbar, kPa, Pa inHg, mmH2 0, mmHg, torr, psia
  • Acceleration sensitivity    negligible
  • Pressure connector M5 (10-32) internal thread
  • Pressure fitting barbed fitting for 1/8” I.D. tubing or quick connector with shutoff valve for 1/8” hose
  • Maximum pressure limit 5000 hPa abs.
  • Compliance EMC standard EN61326-1:1997 + Am1:1998 + Am2:2001: Industrial Environment
Measurement
Barometric pressure range (Class A/B)500–1100 hPa
Barometric pressure range (Class B extended)50–1100 hPa
Linearity (Class A, 500–1100 hPa)±0.05 hPa
Linearity (Class B, 500–1100 hPa)±0.10 hPa
Linearity (Class B, 50–1100 hPa)±0.20 hPa
Hysteresis (500–1100 hPa)±0.03 hPa
Hysteresis (Class B, 50–1100 hPa)±0.08 hPa
Repeatability (500–1100 hPa)±0.03 hPa
Repeatability (Class B, 50–1100 hPa)±0.08 hPa
Calibration uncertainty (Class A)±0.07 hPa
Calibration uncertainty (Class B, 500–1100 hPa)±0.15 hPa
Calibration uncertainty (Class B, 50–1100 hPa)±0.15 hPa
Accuracy at +20 °C (Class A)±0.10 hPa
Accuracy at +20 °C (Class B)±0.20 hPa
Temperature dependence (500–1100 hPa)±0.1 hPa
Temperature dependence (50–1100 hPa)±0.3 hPa
Total accuracy −40 … +60 °C (Class A, 500–1100 hPa)±0.15 hPa
Total accuracy −40 … +60 °C (Class B, 500–1100 hPa)±0.25 hPa
Total accuracy −40 … +60 °C (Class B, 50–1100 hPa)±0.45 hPa
Long-term stability (500–1100 hPa)±0.1 hPa/year
Long-term stability (50–1100 hPa)±0.2 hPa/year
Pressure unitshPa, mbar, kPa, Pa, inHg, mmH2O, mmHg, torr, psia
Resolution (Class A)0.01 hPa
Resolution (Class B)0.1 hPa
Settling time at startup (1 sensor)Class A: 4 s; Class B: 3 s
Response time (1 sensor)Class A: 2 s; Class B: 1 s
Maximum pressure limit5000 hPa absolute
Maximum measurement rate10 Hz
Dimensions (PTB330)183 × 119 × 143 mm (7.20 × 4.69 × 5.63 in)
Weight1–1.5 kg (2.2–3.3 lb)
Housing materialG AlSi10 Mg (DIN 1725)
Pressure fittingBarbed fitting for 1/8-inch (inside diameter) tubing or quick connector with shutoff valve for 1/8-inch hose
Pressure connectorM5 (10-32) internal thread
Outputs
Serial communicationRS-232, RS-485, RS-422
Analog output (optional) – current0–20 mA, 4–20 mA
Analog output (optional) – voltage0–1 V, 0–5 V, 0–10 V
Analog output accuracy at +20 °C (500–1100 hPa)±0.30 hPa
Analog output accuracy at +20 °C (50–1100 hPa)±0.40 hPa
Analog output accuracy at −40 … +60 °C (500–1100 hPa)±0.60 hPa
Analog output accuracy at −40 … +60 °C (50–1100 hPa)±0.75 hPa
Data transfer softwareMI70 Link (requires Microsoft Windows and Microsoft Excel)
Power Requirements
Supply voltage10–35 V DC
Supply voltage sensitivityNegligible
Typical power consumption (RS-232, 24 V DC, 1 sensor)25 mA
Typical power consumption (RS-485, 24 V DC, 1 sensor)40 mA
Output voltage Uout25 mA
Output current Iout40 mA
Display and backlight+20 mA
Environmental
Operating pressure500–1100 hPa, 50–1100 hPa
Operating temperature (without display)−40 … +60 °C (−40 … +140 °F)
Operating temperature (with display)0 … +60 °C (+32 … +140 °F)
Operating humidity0–100 %RH, non-condensing
Storage temperature (without display)−55 … +80 °C (−67 … +176 °F)
Storage temperature (with display)−40 … +80 °C (−40 … +176 °F)
IP ratingIP66; IP65 (NEMA 4) with local display; IP40 for PTB330AWS
Certification & Compliance
EU directives and regulationsRoHS Directive (2011/65/EU) as amended by 2015/863; EMC Directive (2014/30/EU); Low Voltage Directive (2014/35/EU, units with single-phase AC power supply Power-1)
Electrical safetyEN 61010-1:2010 + A1:2019 (units with single-phase AC power supply Power-1)
Electromagnetic compatibility (EMC)EN 61326-1, industrial environment; EN 55011:2009 + A1:2010
EnvironmentalEN IEC 63000:2018