Vaisala WINDCAP Ultrasonic Wind Sensor WMT700

  • WMO and ICAO compliant
  • Measurement range up to 75 m/s
  • Data output rate 0.25 s
  • Heating up to 250 W
  • Body heating option available
  • Self-diagnostics and validation
  • Max. 3600-second average
  • IP66 and IP67
  • Maintenance-free
  • Wind gust calculated according to the WMO guidelines
  • Data format outputs: polar coordinates and vectors
  • Fully compensates effects of temperature, humidity and pressure
  • Three-transducer layout provides accurate data

Vaisala

Category:

Description

Wind Speed

Measurement range
701
0…40 m/s
702
0…65 m/s
703
0…75 m/s
Accuracy+/- 0.1 m/s or 2 % of reading, whichever is greater
Starting threshold0.01 m/s
Resolution0.01 m/s

Wind direction

Measurement range0…360°
Accuracy±2°
Starting threshold0.1 m/s
Resolution0.01°
Measurement
Wind speed observation range (WMT701)0 … 40 m/s (89 mph)
Wind speed observation range (WMT702)0 … 65 m/s (145 mph)
Wind speed observation range (WMT703)0 … 75 m/s (168 mph)
Wind speed observation range (WMT704)0 … 90 m/s (201 mph)
Wind speed starting threshold0.01 m/s (0.0223 mph)
Wind speed resolution0.01 m/s (0.0223 mph)
Wind speed response time250 ms
Wind speed accuracy (0 … 75 m/s)±0.1 m/s (0.2 mph) or 2 % of reading, whichever is greater
Wind speed accuracy (75 … 90 m/s)±5 % of reading
Wind direction observation range0 … 360°
Wind direction starting threshold0.1 m/s (0.2 mph)
Wind direction resolution0.01°
Wind direction response time250 ms
Wind direction accuracy±2°
Readout update interval4 Hz (default) and 8 Hz (optional)
Units availablem/s, knots, mph, km/h, V, mA, Hz
Operating modeAutomatic message or poll mode
Virtual temperatureCelsius degrees
Dimensions (H × W × Ø)348 × 250 × 285 mm (13.70 × 9.84 × 11.22 in)
Weight1.8 kg (4.0 lb)
Body and arms, mounting kit materialStainless steel AISI 316
Transducers materialSilicone
Connector housing surfaceNickel-plated brass
Outputs
Analog output – wind speedVoltage, current, frequency
Analog output – wind directionVoltage, current, potentiometer
Communication interfaces (COM1)RS-485
Communication interfaces (COM2)RS-485, RS-422, RS-232, SDI-12
Communication profilesWMT700, WS425 ASCII, NMEA Standard and Extended (v0183), SDI-12 (v1.3), WS425 ASOS, ROSA MES 12, customized
Bit rate300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200
Available averagesMax. 3600 s
Power Requirements
Operating voltage9 … 36 V DC (absolute max. 40 V DC)
Heating voltage24 … 36 V DC (absolute max. 40 V DC)
Heating power – heated transducers (avg)32 W
Heating power – heated transducers (peak)40 W
Heating power – heated transducers and arms (avg)152 W
Heating power – heated transducers and arms (peak)200 W
Heating power – heated transducers, arms, and body (avg)252 W
Heating power – heated transducers, arms, and body (peak)350 W at 24 V DC
Maritime input voltage range (operating)10 … 30 V DC (−10 … +30 %), per IEC 60945
Maritime input voltage range (heating)24 … 30 V DC (−10 … +30 %), per IEC 60945
Environmental
Heating options0 W, 30 W, 150 W, or 250 W
Operating temperature (no heating)−10 … +60 °C (+14 … +140 °F)
Operating temperature (with heating)−40 … +60 °C (−40 … +140 °F)
Operating temperature (extended heating)−55 … +70 °C (−67 … +158 °F)
Storage temperature−60 … +80 °C (−76 … +176 °F)
IP ratingIP66 and IP67
Certification & Compliance
EU directives and regulationsEMC Directive (2014/30/EU); RoHS Directive (2011/65/EU) amended by 2015/863; REACH Regulation (EC 1907/2006)
EMC immunityIEC 61326-1, IEC 60945
EMC emissionsCISPR 32 / EN 55032, Class B
EnvironmentalIEC 60068-2-1, 2, 6/34, 30, 31, 67, 78; IEC 60529; VDA 621-415
MaritimeIEC 60945, DNVGL-CG-0339
Electrical safetyUL 61010-1; CAN/CSA C22.2 No. 61010-1-12
Compliance marksCE, China RoHS, RCM, UKCA
Listing marksSGS (USA and Canada)
DNV GL Type Examination CertificateNo. TAA00000U5